TRANSFORMER , POWER

Definition:

A TRANSFORMER CONSISTING OF ONE OR MORE PRIMARY WINDING(S) AND ONE OR MORE SECONDARY WINDING(S). IT MAY BE DESIGNED FOR DIRECT CONNECTION TO AN ALTERNATING CURRENT SOURCE FOR PURPOSES OF CHANGING THE SECONDARY VOLTS AND AMPERES OR DESIGNED TO ELIMINATE METALLIC INTERCONNECTION BETWEEN CIRCUITS IN AN OVERALL ONE TO ONE VOLTAGE RATIO, WITH OR WITHOUT ADDITIONAL OUTPUT WINDINGS, OR ITEMS DESIGNED TO AUTOMATICALLY MAINTAIN A CONSTANT OUTPUT VOLTAGE WITHIN SPECIFIED LIMITS UNDER VARYING INPUT OR LOAD CONDITIONS. ALSO INCLUDES ITEMS HAVING A PROVISION FOR MECHANICALLY CHANGING THE TURNS RATIO OR INDUCTIVE COUPLING IN PROGRESSIVE INCREMENTS BY MEANS OF VOLTAGE TAPS, RATIO ADJUSTER, OR DEVICES OE SIMILAR DESIGN. FOR TRANSFORMERS HAVING WINDING(S) COMMON TO BOTH INPUT AND OUTPUT CIRCUITS, SEE TRANSFORMER (1), POWER, AUTOTRANSFORMER. EXCLUDES TRANSFORMER (1), PULSE.

CAGE Information

Code Company
13483 PRECISION ELECTRONICS INC.

Federal Supply Class

Title

COILS AND TRANSFORMERS

Inclusions:

INCLUDES COILS, EXCEPT IGNITION AND MAGNETO; COIL ASSEMBLIES; REACTORS; TRANSFORMERS.

Exclusions:

Characteristics (Decoded)

MRC Requirements Statement Clear Text Reply
AKPV MOUNTING FACILITY QUANTITY 4 SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 110.00 DC POUNDS PER HOUR WET SINGLE COMPONENT 1ST SECONDARY
BPLC WINDING FUNCTION AND QUANTITY 1 PRIMARY SINGLE COMPONENT AND 3 SECONDARY SINGLE COMPONENT
ADAT BODY WIDTH 2.125 INCHES MINIMUM AND 2.250 INCHES MAXIMUM
CRBZ WINDING OPERATING CURRENT 50.0 MILLIAMPERES MAXIMUM OF STANDARD RANGE B SINGLE COMPONENT 1ST SECONDARY
AAJF THREAD DIRECTION (NON-CORE) RIGHT-HAND SINGLE GROUP
ABKQ CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH 1.995 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 2.005 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AARG RELIABILITY INDICATOR NOT ESTABLISHED
CRMJ WINDING POWER RATING 4.7 VOLTS-AMPERES SINGLE COMPONENT 3RD SECONDARY
ABKR CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH 1.620 INCHES MINIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP AND 1.630 INCHES MAXIMUM SINGLE MOUNTING FACILITY SINGLE CENTER GROUP
AKNA INCLOSURE TYPE HERMETICALLY SEALED
CWJS WINDING OPERATING VOLTAGE 27.00 DC POUNDS PER HOUR DRY SINGLE COMPONENT 2ND SECONDARY AND 32.50 DC POUNDS PER HOUR WITH RETAINING CHAIN SINGLE COMPONENT 2ND SECONDARY
AXGY MOUNTING METHOD THREADED STUD SINGLE GROUP
CWJS WINDING OPERATING VOLTAGE 6.30 AC POUNDS PER HOUR WET SINGLE COMPONENT 3RD SECONDARY
CRMJ WINDING POWER RATING 65.0 VOLTS-AMPERES SINGLE COMPONENT 2ND SECONDARY
CRBZ WINDING OPERATING CURRENT 750.0 MILLIAMPERES NOMINAL B SINGLE COMPONENT 3RD SECONDARY
AARD DUMMY TERMINAL QUANTITY (NON-CORE) 2
PKWT UNPACKAGED UNIT WEIGHT (NON-CORE) 4.400 POUNDS
ADAQ BODY LENGTH 2.565 INCHES MINIMUM AND 2.690 INCHES MAXIMUM
ACZB FREQUENCY RATING 48.0 HERTZ MINIMUM SINGLE COMPONENT AND 60.0 HERTZ MAXIMUM SINGLE COMPONENT
ACZX WINDING SHIELDING METHOD INTERNAL SHIELD GROUNDED TO INCLOSURE SINGLE COMPONENT
ACZC INPUT-OUTPUT PHASE RELATIONSHIP SINGLE PHASE TO SINGLE PHASE SINGLE COMPONENT
THSD THREAD SERIES DESIGNATOR UNF SINGLE GROUP
AAJD THREAD CLASS (NON-CORE) 2A SINGLE GROUP
TTQY TERMINAL TYPE AND QUANTITY 12 TURRET
CWJS WINDING OPERATING VOLTAGE 109.25 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 120.75 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 115.00 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 103.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY AND 126.50 AC POUNDS PER HOUR WET SINGLE COMPONENT SINGLE PRIMARY
CQLC WINDING TAP LOCATION (NON-CORE) MULTIPLE TAPS W/O CENTER TAP SINGLE COMPONENT SINGLE PRIMARY
CQJX NOMINAL THREAD SIZE 0.190 INCHES SINGLE GROUP
CRBZ WINDING OPERATING CURRENT 1.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER SINGLE COMPONENT 2ND SECONDARY AND 2.0 AMPERES MAXIMUM OF STANDARD RANGE B AND BETTER DROP SIDING SINGLE COMPONENT 2ND SECONDARY
AEHZ MAXIMUM OPERATING TEMP 155.0 DEG CELSIUS
CRMJ WINDING POWER RATING 5.5 VOLTS-AMPERES SINGLE COMPONENT 1ST SECONDARY
ADAU BODY HEIGHT 4.375 INCHES MINIMUM AND 4.500 INCHES MAXIMUM